17 | B | LSI00330 | LSI | (#14: #3/3): 8-port MegaRAID | SV24333061 |
17 | C | LSI00330 | LSI | (#14: #3/3): 8-port MegaRAID | SV24333240 |
18 | RAID5 | configure | RAID 5: Striping with parity | ||
19 | RAID_Instruct | configure | Configure 1 RAID sets / arrays. | ||
20 | A | SSDSC2CW480A310 | Intel i520 | 480GB, SATA 6Gb SSD | CVCV248004D2480DGN |
20 | B | SSDSC2CW480A310 | Intel i520 | 480GB, SATA 6Gb SSD | CVCV248001KS480DGN |
20 | C | SSDSC2CW480A310 | Intel i520 | 480GB, SATA 6Gb SSD | CVCV248004PK480DGN |
20 | D | SSDSC2CW480A310 | Intel i520 | 480GB, SATA 6Gb SSD | CVCV247604LY480DGN |
20 | E | SSDSC2CW480A310 | Intel i520 | 480GB, SATA 6Gb SSD | CVCV248002HT480DGN |
20 | F | SSDSC2CW480A310 | Intel i520 | 480GB, SATA 6Gb SSD | CVCV248003U4480DGN |
DMI System: ION G1 2012 123548 810FB9F2-F116-E211-A36D-001E676B87D5 Base Board: Intel Corporation S2600GZ QSGR24100872 ION G1 123548 ->Constant Customer Chassis: INTEL Rack Mount Chassis R1208GZ4GC FGBU2475240 ION G1 123548 ->Constant Customer FRU Product | ION | G1 | 2012 | 123548 | ION G1 123548 ->Constant Customer BaseBoard | 00 2012 | Intel Corporation | S2600GZ | QSGR24100872 | G11481-353 Chassis | Rack-Mount Chassis | R1208GZ4GC | FGBU2475240 | INTEL PowerCage PowerSupply1 | DELTA | DPS-750XB A | E98791-007 | 02 | E98791D1238135928 PowerSupply2 | DELTA | DPS-750XB A | E98791-007 | 02 | E98791D1238135818
SDR[0089] FRU 20 03 0a 02 Pwr Supply 2 FRU [PowerSply,20,03] PowerSply FRU Size : 256 [PowerSply,20,03] Product Manufacturer: DELTA [PowerSply,20,03] Product Name : DPS-750XB A [PowerSply,20,03] Product Part Number : E98791-007 [PowerSply,20,03] Product Version : 02 [PowerSply,20,03] Product Serial Num : E98791D1238135828 [PowerSply,20,03] Product Asset Tag : [PowerSply,20,03] Product FRU File ID : [PowerSply,20,03] Multi[0] Power Supply Record : Capacity : 750 W Peak VA : 1744 VA Inrush Current : 55 A Inrush Interval : 5 ms Input Voltage Range1 : 90-140 V Input Voltage Range2 : 180-264 V Input Frequency Range : 47-63 Hz AC Dropout Tolerance : 20 ms Flags : PredictFail PowerFactorCorrect AutoswitchVolt Hotswap DeassertFail Peak Capacity : 850 W for 12 s Combined Capacity : not specified Fan low threshold : 133 RPS SDR[008a] FRU 20 04 0c 01 Front Panel [Board ,20,04] Board FRU Size : 256 [Board ,20,04] Board Mfg DateTime : Tue Aug 28 01:39:00 2012 [Board ,20,04] Board Manufacturer : Intel Corporation [Board ,20,04] Board Product Name : FFPANEL [Board ,20,04] Board Serial Number : QSBT23410105 [Board ,20,04] Board Part Number : G10279-401 [Board ,20,04] Board FRU File ID : FRU Ver 0.01 SDR[008b] FRU 20 05 0f 01 HS Backplane 1 [HotSwapCt,20,05] HotSwapCt FRU Size : 256 [HotSwapCt,20,05] Board Mfg DateTime : Tue Aug 28 15:15:00 2012 [HotSwapCt,20,05] Board Manufacturer : Intel Corporation [HotSwapCt,20,05] Board Product Name : F1U8X25HSBP [HotSwapCt,20,05] Board Serial Number : QSRU23409327 [HotSwapCt,20,05] Board Part Number : G43186-150 [HotSwapCt,20,05] Board FRU File ID : FRU Ver 0.01 [HotSwapCt,20,05] Board OEM Field : SDR[008c] IPMB 20 00 07 01 Basbrd Mgmt Ctlr SDR[008d] IPMB 2c 06 2e 02 Mgmt Engine
BIOS: SE5C600.86B.01.06.0002.110120121539 SE5C600.86B.01.06.0002.110120121539 BIOS Version:......... SE5C600.86B.01.06.0002 BMC Firmware Version: --------------------- Op Code:........... 1.16.4010 Boot Code:......... 01.14 ME Firmware Version:.. 02.01.05.107 SDR Version:.......... SDR Package 1.08
Adapter #0 Versions ================ Product Name : LSI MegaRAID SAS 9271-8i Serial No : SV24333037 FW Package Build: 23.11.0-0021 Mfg. Data ================ Mfg. Date : 10/27/12 Rework Date : 00/00/00 Revision No : 10A Battery FRU : N/A Image Versions in Flash: ================ BIOS Version : 5.38.00_4.12.05.00_0x05240000 WebBIOS Version : 6.1-60-e_60-Rel Preboot CLI Version: 05.07-00:#%00011 FW Version : 3.230.05-2100 NVDATA Version : 2.1301.03-0115 Boot Block Version : 2.05.00.00-0010 Activated Advanced Software Options --------------------------- Advanced Software Option : MegaRAID FastPath Mode : Secured Time Remaining : Unlimited Advanced Software Option : MegaRAID RAID6 Mode : Factory Installed Time Remaining : Unlimited Advanced Software Option : MegaRAID RAID5 Mode : Factory Installed Time Remaining : Unlimited
Storage Virtual Drives Virtual drive : Target Id 0 ,VD name Size : 2.441 TB State : Optimal RAID Level : 5 Adapter #0 Number of Virtual Disks: 1 Virtual Drive: 0 (Target Id: 0) RAID Level : Primary-5, Secondary-0, RAID Level Qualifier-3 Size : 2.441 TB State : Optimal Encryption : None PI type: No PI Number of Spans: 1 Span: 0 # of PDs: 8 PD: 0 Enclosure ID: 252 Slot: 0 Drive's postion: DiskGroup: 0, Span: 0, Arm: 0 Enclosure position: 0 : SATA Online, Spun Up Device Firmware Level: 400i Inquiry Data: CVCV248003HX480DGN INTEL SSDSC2CW480A3 400i Media: Solid State PD: 1 Enclosure ID: 252 Slot: 1 Drive's postion: DiskGroup: 0, Span: 0, Arm: 1 Enclosure position: 0 : SATA Online, Spun Up Device Firmware Level: 400i Inquiry Data: CVCV2480053G480DGN INTEL SSDSC2CW480A3 400i Media: Solid State PD: 2 Enclosure ID: 252 Slot: 2 Drive's postion: DiskGroup: 0, Span: 0, Arm: 2 Enclosure position: 0 : SATA Online, Spun Up Device Firmware Level: 400i Inquiry Data: CVCV248004NZ480DGN INTEL SSDSC2CW480A3 400i Media: Solid State PD: 3 Enclosure ID: 252 Slot: 3 Drive's postion: DiskGroup: 0, Span: 0, Arm: 3 Enclosure position: 0 : SATA Online, Spun Up Device Firmware Level: 400i Inquiry Data: CVCV248002PD480DGN INTEL SSDSC2CW480A3 400i
Processor Information 1 Intel Type 0, Family 6, Model 45, Stepping 7 Intel(R) Xeon(R) E5-2660 0 @ 2.20GHz 2 Intel Type 0, Family 6, Model 45, Stepping 7 Intel(R) Xeon(R) E5-2660 0 @ 2.20GHz 16 processors: Intel(R) Xeon(R) CPU E5-2660 0 @ 2.20GHz MHz : 1200.000 DIMM_A1: 16384 MB, 64 /72 bits, 1600 MHz, Mfr: Samsung , PN: M393B2G70BH0-CK0, SN: 86D6E722 DIMM_A2: DIMM_A3: DIMM_B1: 16384 MB, 64 /72 bits, 1600 MHz, Mfr: Samsung , PN: M393B2G70BH0-CK0, SN: 86D6E738 DIMM_B2: DIMM_B3: DIMM_C1: 16384 MB, 64 /72 bits, 1600 MHz, Mfr: Samsung , PN: M393B2G70BH0-CK0, SN: 86D6E69D DIMM_C2: DIMM_C3: DIMM_D1: 16384 MB, 64 /72 bits, 1600 MHz, Mfr: Samsung , PN: M393B2G70BH0-CK0, SN: 86D6E693 DIMM_D2: DIMM_D3: DIMM_E1: 16384 MB, 64 /72 bits, 1600 MHz, Mfr: Samsung , PN: M393B2G70BH0-CK0, SN: 86D6E741 DIMM_E2: DIMM_E3: DIMM_F1: 16384 MB, 64 /72 bits, 1600 MHz, Mfr: Samsung , PN: M393B2G70BH0-CK0, SN: 86D6E6B3 DIMM_F2: DIMM_F3: DIMM_G1: 16384 MB, 64 /72 bits, 1600 MHz, Mfr: Samsung , PN: M393B2G70BH0-CK0, SN: 86D6E752 DIMM_G2: DIMM_G3: DIMM_H1: 16384 MB, 64 /72 bits, 1600 MHz, Mfr: Samsung , PN: M393B2G70BH0-CK0, SN: 86D6E7F3 DIMM_H2: DIMM_H3: ____________________________________________________________________ MemTotal: 132063012 kB
Network 04:00.0 Ethernet controller: Intel Corporation I350 Gigabit Network Connection (rev 01) 04:00.1 Ethernet controller: Intel Corporation I350 Gigabit Network Connection (rev 01) 04:00.2 Ethernet controller: Intel Corporation I350 Gigabit Network Connection (rev 01) 04:00.3 Ethernet controller: Intel Corporation I350 Gigabit Network Connection (rev 01) eth0 Link encap:Ethernet HWaddr 00:1E:67:6B:87:D5 inet addr:10.0.3.167 Bcast:10.0.3.255 Mask:255.255.255.0 eth1 Link encap:Ethernet HWaddr 00:1E:67:6B:87:D6 UP BROADCAST MULTICAST MTU:1500 Metric:1 eth2 Link encap:Ethernet HWaddr 00:1E:67:6B:87:D7 inet6 addr: fe80::21e:67ff:fe6b:87d7/64 Scope:Link eth3 Link encap:Ethernet HWaddr 00:1E:67:6B:87:D8 inet6 addr: fe80::21e:67ff:fe6b:87d8/64 Scope:Link inet addr:127.0.0.1 Mask:255.0.0.0 RAID 02:00.0 RAID bus controller: LSI Logic / Symbios Logic MegaRAID SAS 2208 [Thunderbolt] (rev 05) 03:00.0 RAID bus controller: LSI Logic / Symbios Logic MegaRAID SAS 2208 [Thunderbolt] (rev 05) 04:00.0 RAID bus controller: LSI Logic / Symbios Logic MegaRAID SAS 2208 [Thunderbolt] (rev 05) SSCSI 03:00.0 Serial Attached SCSI controller: Intel Corporation C600/X79 series chipset Dual 4-Port SATA Storage Control Unit (rev 06) Video Display 0a:00.0 VGA compatible controller: Matrox Electronics Systems Ltd. MGA G200e [Pilot] ServerEngines (SEP1) (rev 05)
000f SDR Full 01 01 20 a 01 snum 20 BB EDGE Temp = 18 OK 24.00 degrees C 0010 SDR Full 01 01 20 a 01 snum 22 SSB Temp = 2b OK 43.00 degrees C 0011 SDR Full 01 01 20 a 01 snum 23 BB BMC Temp = 25 OK 37.00 degrees C 0012 SDR Full 01 01 20 a 01 snum 24 BB P2 VR Temp = 21 OK 33.00 degrees C 0013 SDR Full 01 01 20 a 01 snum 25 BB MEM VR Temp = 1e OK 30.00 degrees C 0014 SDR Full 01 01 20 a 01 snum 2f LAN NIC Temp = 2c OK 44.00 degrees C 0015 SDR Full 01 01 20 m 04 snum 30 System Fan 1 = 27 OK 3822.00 RPM 0016 SDR Full 01 01 20 m 04 snum 32 System Fan 3 = 27 OK 3822.00 RPM 0017 SDR Full 01 01 20 m 04 snum 34 System Fan 5 = 29 OK 4018.00 RPM 0018 SDR Full 01 01 20 m 04 snum 36 Processor 1 Fan = 12 OK 1764.00 RPM 0019 SDR Full 01 01 20 m 04 snum 37 Processor 2 Fan = 11 OK 1666.00 RPM 001a SDR Comp 02 6f 20 a 08 snum 50 PS1 Status = 0001 Present 001b SDR Comp 02 6f 20 a 08 snum 51 PS2 Status = 0001 Present 001c SDR Full 01 01 20 a 01 snum 5c PS1 Temperature = 1e OK 30.00 degrees C 001d SDR Full 01 01 20 a 01 snum 5d PS2 Temperature = 1d OK 29.00 degrees C 001e SDR Comp 02 6f 20 m 07 snum 70 P1 Status = 0080 ProcPresent 001f SDR Comp 02 6f 20 m 07 snum 71 P2 Status = 0080 ProcPresent 0020 SDR Full 01 01 20 a 01 snum 74 P1 Therm Margin = c3 OK -61.00 degrees C 0021 SDR Full 01 01 20 a 01 snum 75 P2 Therm Margin = ca OK -54.00 degrees C 0022 SDR Full 01 01 20 a 01 snum 78 P1 Therm Ctrl % = 00 OK 0.00 percent 0023 SDR Full 01 01 20 a 01 snum 79 P2 Therm Ctrl % = 00 OK 0.00 percent 0024 SDR Comp 02 03 20 a 07 snum 7c P1 ERR2 = 0000 OK 0025 SDR Comp 02 03 20 a 07 snum 7d P2 ERR2 = 0000 OK 0026 SDR Comp 02 03 20 m 07 snum 80 CATERR = 0000 OK 0027 SDR Comp 02 03 20 m 07 snum 81 P1 MSID Mismatch = 0000 OK 0028 SDR Comp 02 03 20 m 07 snum 82 CPU Missing = 0000 OK